Roof & garden cabins
The flat roof is the most under-used room in an Egyptian building, and in a country this hot it is also the co…
Read more →Building a hot room in a country that is already hot sounds absurd until you use one. The trick is not the heat — it is the cold water next to it, and the insulation that keeps the two apart.
Indicative band: 150 – 490 thousand EGP, supplied and installed in Egypt.
Across the continent: Saunas in all eight countries →

In a cold country insulation keeps heat in. In Egypt it also keeps the summer out, which matters more than people expect: an under-insulated cabin on a Cairo roof is absorbing forty degrees of ambient before the heater does anything at all.
We insulate harder here than in Europe — walls, ceiling and floor — and we shade the cabin where the layout allows. A well-insulated, shaded cabin reaches temperature faster, holds it on a third of the duty cycle and costs measurably less to run through July and August.
The sum starts at about 0.85 kW per cubic metre of insulated cabin. Glazing is added at roughly 0.42 kW per square metre because glass loses heat far faster than a wall — and in Egypt it also gains heat from the sun, so a west-facing glass wall is working against you twice a day.
Above 8 kW you want a three-phase supply. Egypt's network runs 220 V single phase and 380 V three phase at 50 Hz.
The khamsin season and ordinary Cairo dust will blanket a chiller condenser, a ventilation grille and a control board in weeks. Every fan we install gets a washable pre-filter, every grille faces away from the prevailing dust, and the service interval here is three months rather than six.
This is not a sales upsell. It is the single commonest reason equipment in Egypt fails early, and it is entirely preventable.
With a cold plunge beside it and the session in the evening, yes, and it is one of the most used rooms in the house. Without cold water it is a hard sell from June to September and we would rather say so.
Six to ten weeks from signed drawing, or three to four if we have the section in stock. Shipping lands at Alexandria or Damietta and inland haulage is short.
Usually yes — a cabin is light. A plunge tub full of water is not, and that needs the slab checked before we quote.

The flat roof is the most under-used room in an Egyptian building, and in a country this hot it is also the co…
Read more →
In a Maadi or Zamalek apartment there is rarely three-phase power, a spare drain or four square metres going f…
Read more →
Egyptian mains water is hard and often high in dissolved solids. That single fact kills more steam generators …
Read more →